<?xml version="1.0" encoding="UTF-8" ?>
<feed xmlns="http://www.w3.org/2005/Atom">
    <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/?sAtom=1" rel="self" type="application/atom+xml"/>
    <author>
        <name>Gottinger Online-Shop</name>
    </author>
    <title>ankle joints</title>
    <id>https://shop.gottinger.de/en-en/products-/ankle-joints/?sRss=1</id>
    <updated>2026-04-29T17:23:43+02:00</updated>
            
            <entry>
                <title type="text">Carbon spring &#039;Split Spring Active&#039;</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/35/carbon-spring-split-spring-active?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/35/carbon-spring-split-spring-active?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The Split Spring Active Carbon spring is a variant of the Split Spring Carbon spring for very active patients and patients with a rotation through 10 °. The Split Spring® and Split Spring® Active are further developments of the standard carbon Spring® and allow an enlarged ran...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The Split Spring Active Carbon spring is a variant of the Split Spring Carbon spring for very active patients and patients with a rotation through 10 °. The Split Spring® and Split Spring® Active are further developments of the standard carbon Spring® and allow an enlarged range of plantar flexion. This leads to a reduction of the hind-foot leverage. The gait of the patient will be more fluid, energy saving and physiological. The spring adapts better to any surface and even an inclined plane will be managed a lot easier. Benefits: antar flexion possible more fluid, energy saving and physiological gait adapts better to any surface low noise level c osmetically favorable aspects due to the dorsal installation low maintenance low weight Area of application: for all paralyses and for partial paralyses, where the function of the plantar flexions has to be compensated for highly active patients for KAFO and AFO Contraindication: no combination with a reciprocating hip joint system possible Attention: The Spring® is NOT calculated according to WEIGHT, but will be determined by body weight, height, level of physical activity and diagnosis. Please use the configurator to supply you with the correct Spring®.
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">Carbon spring Split Spring</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/78/carbon-spring-split-spring?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/78/carbon-spring-split-spring?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The Split Spring® is a further development of the standard carbon Spring® and allows an enlarged range of plantar flexion. This leads to a reduction of the hind-foot leverage. The gait of the patient will be more fluid, energy saving and physiological. The spring adapts better...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The Split Spring® is a further development of the standard carbon Spring® and allows an enlarged range of plantar flexion. This leads to a reduction of the hind-foot leverage. The gait of the patient will be more fluid, energy saving and physiological. The spring adapts better to any surface and even an inclined plane will be managed a lot easier. Benefits: antar flexion possible more fluid, energy saving and physiological gait adapts better to any surface low noise level c osmetically favorable aspects due to the dorsal installation low maintenance low weight Area of application: for all paralyses and for partial paralyses, where the function of the plantar flexions has to be compensated for KAFO and AFO Contraindication: no combination with a reciprocating hip joint system possible Attention: The Spring® is NOT calculated according to WEIGHT, but will be determined by body weight, height, level of physical activity and diagnosis. Please use the configurator to supply you with the correct Spring®.
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">Carbon spring &#039;Spring Active&#039;</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/33/carbon-spring-spring-active?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/33/carbon-spring-spring-active?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The Spring Active Carbon spring is a variant of the Split Spring Carbon spring for very active patients and patients with a rotation through 10 °. The Spring carbon spring is a type of ankle system that offers patients many advantages over articulated designs. It is possible f...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The Spring Active Carbon spring is a variant of the Split Spring Carbon spring for very active patients and patients with a rotation through 10 °. The Spring carbon spring is a type of ankle system that offers patients many advantages over articulated designs. It is possible for the carbon spring to take in energy during the heel strike and stance phase and to return it in the heel-off phase. In this way, the patient can even run and jump in a well coordinated way. Benefits: more fluid, energy saving and physiological gait low noise level c osmetically favorable aspects due to the dorsal installation low maintenance low weight 30% more performance than the standard Spring Area of application: or all paralyses and for partial paralyses, where the function of the plantar flexions has to be compensated for indication &quot;Pes calcaneus&quot; with active tibialis anterior for highly active patients for KAFO and AFO Contraindication: no combination with a reciprocating hip joint system possible Attention: The Spring® is NOT calculated according to WEIGHT, but will be determined by body weight, height, level of physical activity and diagnosis. Please use the configurator to supply you with the correct Spring®.
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">Carbon spring &#039;Spring&#039;</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/32/carbon-spring-spring?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/32/carbon-spring-spring?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The Spring® carbon spring is a type of ankle system that offers patients many advantages over articulated designs. It is possible for the carbon spring to take in energy during the heel strike and stance phase and to return it in the heel-off phase. In this way, the patient ca...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The Spring® carbon spring is a type of ankle system that offers patients many advantages over articulated designs. It is possible for the carbon spring to take in energy during the heel strike and stance phase and to return it in the heel-off phase. In this way, the patient can even run and jump in a well coordinated way. Benefits: more fluid, energy saving and physiological gait low noise level c osmetically favorable aspects due to the dorsal installation low maintenance low weight Area of application: for all paralyses and for partial paralyses, where the function of the plantar flexions has to be compensated for KAFO and AFO Contraindication: no combination with a reciprocating hip joint system possible Attention: The Spring® is NOT calculated according to WEIGHT, but will be determined by body weight, height, level of physical activity and diagnosis. Please use the configurator to supply you with the correct Spring®.
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">Block knee and ankle joint</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/37/block-knee-and-ankle-joint?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/37/block-knee-and-ankle-joint?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The single-axis Block joint is a very versatile ankle and knee joint. The desired position of the joint can be achieved by filing the frontal stopping surface of the lower joint part. The Block joint is a simple and efficient solution to safely lock the knee. For sitting it ca...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The single-axis Block joint is a very versatile ankle and knee joint. The desired position of the joint can be achieved by filing the frontal stopping surface of the lower joint part. The Block joint is a simple and efficient solution to safely lock the knee. For sitting it can ealily be unlocked. Benefits: accidental unlocking not possible very few maintenance waterproof little wear due to self-lubricating sliding discs and a rotation-proof bush Area of application: for HKAFO, KAFO and AFO Application index for Block as knee joint: Block 19 Aluminum : body weight of up to 12 kg Block 22 Aluminum : body weight of up to 15 kg Block 25 Aluminum: body weight of up to 20 kg Block 28 Aluminum : body weight of up to 30 kg Block 32 Aluminum : body weight of up to 50 kg Block 36 Aluminum : body weight of up to 65 kg Block 36 Plus Titan : body weight of up to 90 kg Application index for Block as ankle joint: Block 19 Aluminum : body weight of up to 15 kg Block 22 Aluminum : body weight of up to 20 kg Block 25 Aluminum: body weight of up to 30 kg Block 28 Aluminum : body weight of up to 50 kg Block 32 Aluminum : body weight of up to 65 kg Block 36 Aluminum : body weight of up to 80 kg Block 36 Plus Titan : body weight of up to 100 kg Further information about the dimensions of the BLOCK knee / ankle Joint can be found here .
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">Sprinter ankle joint aluminum</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/10/sprinter-ankle-joint-aluminum?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/10/sprinter-ankle-joint-aluminum?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The Sprinter is a single-axis ankle joint which allows flexion/extension motion in a restricted sphere. The foot-lifting function is made possible during the stance phase through continuous joint resistance. Its kinetic swing can be altered variably or fixed each time in order...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The Sprinter is a single-axis ankle joint which allows flexion/extension motion in a restricted sphere. The foot-lifting function is made possible during the stance phase through continuous joint resistance. Its kinetic swing can be altered variably or fixed each time in order to lock the joint temporarily (e.g. post-operatively) or to adjust the foot position due to improved motion ratios. Benefits: disassembling of main axis for extension stop adjustment not required interchangeable wedges available in different graduations: 0°; 1,5°; 3°, 4,5°; 6°; 8°; 10°; 12,5° separate dorsal and frontal extension stops available Area of application: body weight of up to max 65 kg for HKAFO, KAFO and AFO Application index: Sprinter 19: body weight of up to 15 kg Sprinter 22: body weight of up to 20 kg Sprinter 25: body weight of up to 30 kg Sprinter 28: body weight of up to 50 kg Sprinter 32: body weight of up to 65 kg Further information about the dimension of the SPRINTER ankle Joint can be found here . Scope of delivery: incl. extension set: Sprinter 19: 6 x 13 x 210mm / Spinter 22: 6 x 13 x 250mm / Sprinter 25: 6 x 16 x 250mm / Sprinter 28 and Sprinter 32: 6 x 19 x 300mm incl. countersunk screws: Sprinter 19: M4 x 7mm / Sprinter 22 and Sprinter 25: M5 x 10mm / Sprinter 28: M6 x 12mm / Sprinter 32: M6 x 14mm
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">SPRINTER plus ankle joint (titanium)</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/251/sprinter-plus-ankle-joint-titanium?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/251/sprinter-plus-ankle-joint-titanium?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The SPRINTER PLUS is a single-axis ankle joint which allows flexion/extension motion in a restricted range. The foot-lifting function is made possible during the stance phase through continuous joint resistance. Its kinetic swing can be altered variably or fixed, in order to l...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The SPRINTER PLUS is a single-axis ankle joint which allows flexion/extension motion in a restricted range. The foot-lifting function is made possible during the stance phase through continuous joint resistance. Its kinetic swing can be altered variably or fixed, in order to lock the joint temporarily (e.g. post-operatively) or to adjust the foot position due to improved motion ratios. The SPRINTER PLUS is the titanium version of the sprinter ankle joints. It is particularly suitable for adults. It is less suspectible to wear than the aluminum version. In addition, a patient with higher body weight can use a smaller joint. Benefits: no need of disassembling the main axis for extension stop adjustment interchangeable wedges available in different graduations: 0°; 1,5°; 3°, 4,5°; 6°; 8°; 10°; 12,5° separate dorsal and frontal extension stops available the titanium version is less susceptible to wear in comparison with the aluminium version Area of application: body weight of up to max 65 kg for HKAFO, KAFO and AFO Application index: Sprinter 19 plus: body weight of up to 20 kg Sprinter 22 plus: body weight of up to 35 kg Sprinter 25 plus: body weight of up to 50 kg Sprinter 28 plus: body weight of up to 90 kg Further information about the dimension of the SPRINTER ankle Joint can be found here . Scope of delivery: incl. extension set incl. countersunk screws: Sprinter 19 plus: M4 x 7mm / Sprinter 22 plus and Sprinter 25 plus: M5 x 10mm / Sprinter 28 plus: M6 x 12mm Additional offer: We manufacture orthoses with SPRINTER plus ankle joint in service production. Please fill out the form &quot;Request orthotics service production&quot; and send it to us. Afterwards you will receive a corresponding offer from us. More information about our offer of service production can be found here. Further Information Excerpt from the article &quot;Experiences on lesion-specific orthotic treatment in patients with spina bifida according to the Berlin concept&quot; from OT 1/13. (Read the whole article.) Lower leg orthoses with the Sprint unilateral ankle joint should have a template of dorsiflexion at an angle of 5 to 8° (with shoe). The upper ankle joint should be limited to 90° to bring the large knee extensor in good working position for the righting loop of the body against the force of gravity in the knee. A setting of 82 to 84° is optional. The upper jump joint should have a range of motion of 15 to 20°. The Sprinter joint is designed so that each wedge restricts dorsiflexion and plantarflexion. These wedges can be quickly removed during fitting to adjust the angle, without disassembling the joint axis.
                    ]]>
                </content>

                            </entry>
        
            
            <entry>
                <title type="text">SPRINTER SUPPORT ankle joint</title>
                <id>https://shop.gottinger.de/en-en/products-/ankle-joints/2677/sprinter-support-ankle-joint?c=37</id>
                <link href="https://shop.gottinger.de/en-en/products-/ankle-joints/2677/sprinter-support-ankle-joint?c=37"/>
                <summary type="html">
                    <![CDATA[
                    
                                                    The SPRINTER SUPPORT is another variant of the SPRINTER ankle joint. The attached gas pressure spring supports the dorsal extension of the foot. The gas pressure spring is available in different strengths and can be replaced if necessary. Due to the different interchangeable w...
                                            ]]>
                </summary>
                <content type="html">
                    <![CDATA[
                    The SPRINTER SUPPORT is another variant of the SPRINTER ankle joint. The attached gas pressure spring supports the dorsal extension of the foot. The gas pressure spring is available in different strengths and can be replaced if necessary. Due to the different interchangeable wedges, the range of motion can be adjusted at any time. Benefits: The gas springs are interchangeable. The gas springs are available in various forces (10 N to 100 N) Interchangeable wedges are available in different graduations (0°; 1.5°; 3°; 4.5°; 6°; 8°; 10°; 12.5°), and the range of motion can be individually adjusted by filing the wedges. The dorsal and frontal stops are replaceable separately. Area of application: for AFO, KAFO and HKAFO For all paralysis or paresis where the function of the dorsal extensors needs to be compensated or the plantar flexion should be dampened. Application index: Sprinter Support 19: body weight of up to 20 kg Sprinter Support 22: body weight of up to 35 kg Sprinter Support 25: body weight of up to 50 kg Sprinter Support 28: body weight of up to 90 kg Scope of delivery: incl gas spring 8/3 incl. extension set (aluminium) incl. 0° dorsal stop wedge and 0° frontal stop wedge (installed upon delivery).
                    ]]>
                </content>

                            </entry>
        
    </feed>